Is Type 1 ventilation necessary? How to calculate the cost-effectiveness of Type 1 ventilation compared to Type 3 ventilation yourself.
Key points of this article
- In a typical 120m² house, heat loss is 73% by conduction and 27% by ventilation. The better the insulation, the higher the proportion of ventilation loss.
- With a type 1 ventilation system (80% heat exchange), the total heat loss of the house is reduced to about 78% of that of a type 3 ventilation system.
- According to calculations in Akashi, the annual savings on heating and cooling from a single-type ventilation system is approximately 1.8 yen. However, the electricity cost for ventilation increases by 5,796 yen per year.
- The net benefit is approximately 1.2 yen per year. Even if the catalog specifications are accurate, it will take 24 to 33 years to recoup the 40 yen difference in construction costs.
- The effect is more pronounced in Hokkaido, Tohoku, and the Sea of Japan side of Japan, but it is less effective in warmer climates where heating and cooling are only used when people are indoors.
Where does the heat from a house escape from in the first place?
Heat loss in a house is the sum of "conduction heat" that escapes through walls, windows, floors, and roofs, and "ventilation heat" carried by the air exchanged during ventilation. The national energy-saving calculation is based on a house with a total floor area of 120 m² (10 m long x 6 m wide, with a ceiling height of 2.5 m and two stories).
This house has a surface area of 280 m² and a volume of 300 cubic meters. The Building Standards Act requires ventilation of half the volume (0.5 air changes) per hour, so the ventilation rate is 150 cubic meters/hour.
We will calculate this using a UA value of 0.5 and an internal/external temperature difference of 10 degrees. The heat lost by conduction is "0.5 × 280 × 10 = 1,400 watts". This is equivalent to the heat generated by two heated tables (kotatsu) or 14 people.
The heat lost through ventilation is calculated using the air constant of 0.35: "0.35 × 150 × 10 = 525 watts". Of the total 1,925 watts, conduction accounts for 73% and ventilation accounts for 27%. The better the insulation, the larger this proportion of ventilation becomes.
The airtightness performance, which is a prerequisite for whether ventilation is effective, is discussed in terms of the C-value and the required level of airtightness .
How much does heat loss decrease when switching to a single-stage ventilation system?
Type 1 ventilation is a type of heat exchange ventilation that recovers heat between the supply and exhaust air. If the heat exchange efficiency is 80%, the amount of heat lost through ventilation will be reduced to "525 × (100 - 80) ÷ 100 = 105 watts".
The total heat loss for the entire house is 1,505 watts, which is the sum of 1,400 watts from conduction and 1,925 watts from ventilation. This is approximately 78% less than the 1,925 watts from a standard ventilation system.
| Ventilation method | Heat loss due to ventilation | Total heat loss for the entire house (1,400W conduction + ventilation) |
|---|---|---|
| Type 3 ventilation | 525W | 1,925W |
| Type 1 ventilation (heat exchange efficiency 80%) | 105W | 1,505W (approximately 78% of Type 3 ventilation) |
From here, we will use actual data from Akashi City, Hyogo Prefecture, where the sender's office is located, to make our calculations. We will use the average temperature data, which anyone can download from the Japan Meteorological Agency website.
The average temperature in winter (November to March) was 7.9 degrees Celsius, and the average temperature in summer (June, August, and September) was 25.9 degrees Celsius. Calculations are based on setting the room temperature to 20 degrees Celsius in winter and 24 degrees Celsius in summer. The higher the room temperature (lower in summer), the more effective insulation and ventilation become.
How much can you actually save with a single-type ventilation system?
The amount of heat saved by a single-type ventilation system is an average of 558 watts/hour in winter. If we calculate this over 150 days/24 hours in winter, with an effective heating efficiency of 3 and an electricity price of 28 yen/kWh, it results in an annual saving of approximately 17,071 yen.
This is merely a simplified calculation. A proper simulation software would yield ¥14,610, which falls within the margin of error.
In summer, heat exchange reduces incoming heat by about a quarter, but the amount of heat saved is only a small 63 watts/hour. Calculated over 90 summer days, the savings would be 762 yen, while the simulation showed a savings of 439 yen.
A simple calculation shows that the savings from heating and cooling combined in winter and summer amount to approximately 17,833 yen per year. Simulations also show an estimate of around 15,000 yen, which doesn't deviate significantly even if the region changes.
What is the net benefit after deducting the electricity cost for ventilation?
The net benefit is the amount remaining after subtracting the increased power consumption due to ventilation from the savings on heating and cooling. Ignoring this point will lead to a wrong decision.
A Type 1 ventilation system (150 cubic meter class) consumes 39 watts of power. On the other hand, even using three 50 cubic meter units for a Type 3 ventilation system, the total power consumption is only about 3 watts. The difference is 36 watts.
If we calculate this 36 watts over 24 hours a day for 240 days, it comes out to 207 kWh, which amounts to 5,796 yen in electricity costs per year. In other words, the electricity cost for ventilation itself is cheaper with a type 3 ventilation system.
Subtracting the 5,796 yen increase in ventilation electricity costs from the 17,833 yen in savings from heating and cooling, the net benefit of a single-type ventilation system is approximately 12,000 yen per year.
| Item | Simple calculation | simulation |
|---|---|---|
| Saving on heating during winter (150 days) | About 17,071 yen | ¥14,610 |
| Saving on air conditioning during summer (90 days) | ¥762 | ¥439 |
| Total savings on heating and cooling | About 17,833 yen | About 15,000 yen |
| Increased electricity costs for ventilation (36W x 24 hours x 240 days = 207kWh) | -5,796 yen | |
| Net Benefits | About 12,000 yen |
How many years will it take to recoup the difference in construction costs?
The payback period for construction costs is calculated by dividing the difference in initial costs by the net benefit each year. This is the most important point for the homeowner to consider.
A ducted ventilation system (Type 1) costs approximately 400,000 yen more to install than a Type 3 ventilation system. Dividing this by the annual benefit of approximately 12,000 yen, it would take about 33 years to recoup the cost. A ductless system costs about 300,000 yen more, and the recoup period is about 24 years.
However, just like car fuel efficiency, ventilation equipment doesn't always perform as advertised. In reality, it's about 70% of the catalog value. Taking this into account, the payback period extends to 67 years for ducted systems and 50 years for ductless systems.
| Way | Difference in construction costs compared to Type 3 ventilation | Payback period (catalog value) | Recovery period (actual measurement = approximately 70% of the catalog value) |
|---|---|---|---|
| Ducted type | About 40 yen | About 33 year | About 67 year |
| Ductless type | About 30 yen | About 24 year | About 50 year |
Furthermore, Type 1 ventilation requires maintenance costs such as filter replacement. Type 3 ventilation only requires sponge filters for the natural air intake and fan replacement once every 10 years, resulting in significantly lower maintenance costs.
What types of houses are suitable and unsuitable for a single-type ventilation system?
In terms of consistently supplying fresh air, Type 1 ventilation is clearly superior to Type 3 ventilation. The decision depends not only on cost-effectiveness but also on the region and lifestyle.
This system is best suited for Hokkaido, Tohoku, and the Sea of Japan side of Japan. In areas where solar heat gain is almost nonexistent, the advantages of this type of ventilation system become clearly apparent, even from calculations.
Conversely, the least effective situation is living in a warm climate where you only heat or cool the rooms you're in. In this case, the benefits of a type 1 ventilation system are not apparent. You can determine whether you should install it by calculating based on the average temperature and room temperature settings for your region.
The relationship between ventilation and stuffiness is explained in the frequently asked question, "Doesn't a highly airtight house make it stuffy?"
Summary
The homeowner can determine the pros and cons of a single-type ventilation system by following these steps.
- Check the average winter and summer temperatures for your region on the Japan Meteorological Agency website.
- Calculate the amount of savings on heating and cooling costs (approximately 1.8 yen per year in Akashi).
- Subtract the increased electricity cost for ventilation (approximately 5,796 yen per year).
- Divide the difference in construction costs by the net benefit to calculate the payback period.
If you live in a warm climate and only use heating and cooling when you're inside the house, there's no need to force yourself to choose a single-stage ventilation system. First, improve insulation and airtightness, and then check the numbers to see if it suits your lifestyle.
FAQ
- What is the difference between Type 1 ventilation and Type 3 ventilation?
-
Type 1 ventilation is a type of heat exchange ventilation where both the supply and exhaust of air are mechanically operated, and heat is recovered in the process. Type 3 ventilation uses mechanical exhaust only, with the supply of air taken in through natural air inlets. Because heat is recovered, Type 1 ventilation can reduce ventilation heat loss.
- How much cheaper will heating costs be if I switch to a single-type ventilation system?
-
In Akashi, the estimated annual savings on heating and cooling costs is approximately 17,833 yen. However, Type 1 ventilation consumes a lot of electricity, adding 5,796 yen to the annual electricity bill for ventilation. The net benefit after deducting these costs is estimated to be around 12,000 yen per year.
- How much more expensive is the installation of a Type 1 ventilation system?
-
Compared to a three-stage ventilation system, the ducted type costs approximately 400,000 yen more, and the ductless type costs approximately 300,000 yen more. Dividing this by the annual benefit of approximately 12,000 yen, the payback period is 24 to 33 years according to the catalog.
- In which areas is Type 1 ventilation particularly effective?
-
These are cold regions such as Hokkaido, Tohoku, and the Sea of Japan side, where solar radiation gain in winter is not expected. The greater the temperature difference between the inside and outside, the greater the effect of heat exchange, so in these regions, the return on investment is likely to be higher, even from a calculation perspective.
- Are there any points to be careful about even with a single-type ventilation system?
-
The main concern is the potential for contamination inside the ducts. While Type 1 ventilation excels at reliably supplying fresh air, the ease of cleaning the ducts and the maintenance costs every 5 or 10 years must also be considered when making a decision.