Air conditioner capacity isn't determined solely by the room size (in tatami mats). This article explains how to determine the appropriate capacity using a free tool from the Central Research Institute of Electric Power Industry, why a 10-tatami unit is sufficient for an 18-tatami LDK, and the basis for the limitation of 4kW and above.

Key points of this article

  • The capacity of an air conditioner cannot be determined without considering four conditions: insulation, window orientation, region, and operating method.
  • There is a free tool available to make this determination. It is provided by the Central Research Institute of Electric Power Industry, a think tank of the 10 major power companies.
  • Even in an 18-tatami mat LDK, with G2 level insulation, the top-scoring system is 2.8kW (equivalent to a 10-tatami mat room).
  • Looking solely at electricity costs, 4kW is the cheapest. This aligns with the conclusion Matsuo has repeatedly stated.
  • The tool does not take into account the open space above the living room. If there is an open space above the living room, choose a larger one.

table of contents

  1. Why isn't the air conditioner capacity determined solely by the room size (in tatami mats)?
  2. Are there any free tools that can determine storage capacity?
  3. How detailed can the tool be in its settings?
  4. How should I interpret the results?
  5. Is it true that there's no point in buying an air conditioner with a capacity of 4kW or more?
  6. Is there a way to shop at a mass retailer without losing money?

Why isn't the air conditioner capacity determined solely by the room size (in tatami mats)?

Choosing the right air conditioner capacity means determining the required capacity based on the amount of heat entering and leaving the room, not the size of the room. Matsuo receives countless questions like, "What capacity should I choose for my house?", but he can't answer most of them because the information is insufficient.

Four conditions are necessary to answer.

necessary conditions Why is it necessary?
Thermal insulation The amount of heat escaping changes. Even with the same area, the required capabilities change.
How many windows are there on the west and east sides? The amount of sunlight entering the room greatly affects the cooling load.
Region The outside temperature conditions are changing.
How to drive The results can be reversed depending on whether you leave it on 24 hours a day or only when you're using it.

If these four factors are not met, it is impossible to select the appropriate capacity. The premise that capacity can be determined solely by "how many tatami mats it is" is simply not valid.

Even if you're not good at calculations, you can still make a judgment.

The answer can be obtained by performing a heat loss calculation. However, many people are not good at calculations. That's why Matsuo is introducing a free website that allows you to determine the appropriate capacity simply by clicking. Below, we will go through how to use it.


The reason why the tatami mat size indication itself is unreliable is that air conditioners are only sold in sizes for 6, 10, and 14 tatami mats.

Are there any free tools that can determine storage capacity?

The air conditioner selection tool is a free simulation tool published by the Central Research Institute of Electric Power Industry (ASST). This institute is a think tank for the 10 major electric power companies, from Hokkaido Electric Power to Okinawa Electric Power, and is comprised of researchers who have completed doctoral programs. You can find it by searching for "ASST" on Google.

The information is provided by research institutions of 10 power companies.

This tool was created by researchers specializing in air conditioning research at a think tank comprised of elite professionals from major Japanese power companies. It is not just any simulation tool.

Matsuo learned about this tool when a researcher at the institute, who had read his book "Eco-Houses Are Actually Cheap," contacted him saying they wanted to meet and exchange ideas. He was invited to the institute, which is usually off-limits, to exchange ideas directly. What sets this simulation apart from others is that Matsuo himself was able to confirm the accuracy of the content because he met and spoke with the person who created the tool.

It had existed for five years but was unknown.

This tool already existed when Matsuo first introduced it, but it was largely unknown to the public because it wasn't widely advertised. Then, five years later, in January 2026, a major version upgrade was implemented. We'll look at the improvements in the next chapter.

Matsuo has stated that he obtains permission from the provider before broadcasting the screenshots of this tool in his videos. Similarly, permission must be obtained before publishing screenshots of the tool on your own website or social media.


How detailed can the tool be in its settings?

The improved tool now allows users to select all 47 prefectures and insulation performance levels up to HEAT20 G2. Before the improvement, only five regions were available, and insulation performance could only be selected up to the current minimum standard for new homes.

Two limitations were removed in the January 2026 update.

Item Before improvement After improvement
Regional Selection Only 5 locations (Morioka, Sendai, Tokyo, Osaka, Fukuoka) All 47 prefectures
Upper limit of thermal insulation performance Next-generation energy-saving standards (current minimum standards for newly built homes) HEAT20 G2 level (two levels above the next generation)

Before the improvements, Matsuo himself had requested the provider to "add at least eight climate zones, and also create buttons for G1 and G2." Both of those requests have now been fulfilled.

It's important to note the next-generation energy-saving standards offered as options. These are also known as the 2013 and 2016 standards, and represent a UA value of 0.87 and a Q value of 2.7. These are the minimum standards for new homes today, and not the target values ​​for highly insulated homes. After the improvements, it became possible to select up to G2, two levels higher than this.

The driving pattern can also be set to "only when present".

The default settings for the tool are 20 degrees Celsius for heating and 24 degrees Celsius for cooling. Here are the recommended settings from Matsuo:

Item National energy conservation calculation standards Matsuo's recommendation
Air conditioning setting temperature 27 degrees 26 degrees (many people find 27 degrees too hot)
Heating temperature setting 20 degrees 23 degrees (Many people find 20 degrees too cold)

Operating times can be set separately for weekdays and weekends, with time slots available for each. You can choose to use it "only when you're there," such as turning it on from 6 am to 9 am and after 18 pm, or you can choose 24-hour continuous operation. The most common option used by the general public is "only when you're there."

Matsuo recommends 24-hour air conditioning operation, but there is a condition: it is only applicable to houses with adequate roof insulation and sun shading. Running air conditioning 24 hours a day in a house without adequate sun shading will result in high electricity bills.


How should I interpret the results?

The key to interpreting the evaluation results is to look at the three indicators—"cost saving," "startup time," and "CO2 reduction"—by switching between them, rather than just focusing on the overall score. Since the top-ranked model changes depending on the indicator, looking only at the overall score will lead you to choose an answer that doesn't suit your usage.

The result for an 18-tatami mat LDK is 2.8kW.

Based on the following conditions—Hyogo Prefecture, 1st floor, southeast corner, 18 tatami mat LDK, G2 level insulation, and "cooling only when used"—the results for mid-to-high-end models are as follows:

Indicators to look at Recommended capacity Remarks
Overall score (emphasis on cost reduction) 2.8kW In terms of tatami mat size, it corresponds to a 10-tatami mat room.
Rising Larger capacity Larger models work faster.
CO2 reduction (emphasis on electricity costs) 4kW This aligns with Matsuo's repeated conclusion that "4kW is the cheapest option."

The results show that a 10-tatami mat size air conditioner is sufficient for an 18-tatami mat living/dining/kitchen area. This is a significant difference from the usual recommendation of 18-tatami mat size air conditioners at mass retailers. This means that with G2 level insulation performance, a small air conditioner is sufficient without having to leave it on constantly.

Do not misunderstand the definition of "cost".

The "cost" displayed in this tool is the sum of the equipment purchase price and 10 years of heating and cooling costs. If you select 2.8kW, it will display 42 yen.

On the other hand, "CO2 reduction" is an indicator that only looks at running costs and does not include the price of the equipment. That's why you might choose "I want to lower costs" but not be able to shift towards CO2 reduction. It's the difference between including or not including initial costs.

High-end and entry-level models have opposite characteristics.

Classification Initial cost electric bill Examples of CO2 emissions
High-performance models (mid-to-high-end models) high cheap 4kW, 3,195kg
Popular models (low-priced models) cheap high It will increase to approximately 4,000 kg.

Switching to a standard model will lower the displayed cost from 42 yen because the price of the equipment will decrease. However, CO2 emissions will increase from around 3,200 kg to approximately 4,000 kg. This means that more electricity is being used. The standard model also has a significantly lower maximum capacity.


Is it true that there's no point in buying an air conditioner with a capacity of 4kW or more?

The statement "they're the same above 4kW" refers to the fact that the maximum heating capacity plateaus around 4kW. Matsuo has repeatedly stated this, and the fact that this tool shows 4kW as the cheapest option when looking only at electricity costs supports this.

The actual number of startup times serves as evidence.

Even with the same 5.6kW rating, there can be about a 1% difference in startup time between entry-level and high-end models. Since the speed varies depending on the model's grade, judging solely by the capacity number will not reflect the actual user experience.

Within the same performance group, the maximum capacity is almost the same, so the difference in start-up time from 4kW to 6.3kW falls within the margin of error. Even when the capacity differs by 1.8 times, such as between 4kW and 7kW, there is almost no difference in start-up time. The conclusion that there is no point in buying a heater with a capacity of 4kW or more for heating purposes can be derived from these actual figures.

However, caution is also needed in the opposite direction.

On the other hand, if you frequently switch the device on and off, smaller models will take longer to start up. Switching the indicator to "startup time" will show that the recommended models are based on the room size, as suggested by retailers and catalogs, assuming this type of usage.

The recommended model will differ depending on whether you're using a highly insulated, airtight house with continuous operation or a house where you're repeatedly switching the air conditioner on and off. It's not a matter of one being right or wrong; you need to choose the model that best suits your usage.


Is there a way to shop at a mass retailer without losing money?

The key to buying at a mass retailer is to specify the model number without mentioning the room size in tatami mats. The moment you tell them the room size, they won't show you any smaller models. The most reliable method is to use a tool to determine the capacity, convert it to a model number, and then go to the store.

Buy by product number without specifying the number of tatami mats.

The most reliable method is to use a tool beforehand to determine the correct model number and then specify, "I'd like this model number." Delivery and installation companies won't leave saying, "This is too small for this room." Even if they ask how many tatami mats it will be used in, simply provide the model number without answering.

Understand the limitations of the tool.

This tool is useful, but it also has limitations. Matsuo points out that the biggest thing to be aware of is that it doesn't take into account the open-plan living room with a high ceiling.

  • If there is an open atrium, it is safer to choose a larger model than the one indicated by the assessment result.
  • The conditions for solar heat gain are not designed to be exactly the same as those for your own house.
  • Therefore, the results should be treated as approximate.

Even so, there is no other tool that is this easy to use and produces such accurate results. Trying out several patterns under your own conditions and switching and comparing the indicators is the best way to avoid being swayed by the recommendations of mass retailers.


The number of units needed to heat and cool an entire house is explained in the frequently asked question, " Can I heat and cool an entire house with just two air conditioners?"

Summary: Capacity is determined by "4 conditions" and "3 indicators".

You can determine the appropriate air conditioner capacity yourself by keeping the following five points in mind.

  1. Four conditions must be met: insulation, window orientation, region, and driving method. Without these, there is no answer.
  2. Determined using a tool from the Central Research Institute of Electric Power Industry — Supports all 47 prefectures and up to G2 level.
  3. Switching between 3 indicators – the top-ranked model changes in cost-saving, startup time, and CO2 reduction.
  4. Heating capacity plateaus above 4kW — 4kW is the cheapest option in terms of electricity costs alone.
  5. If there's an open atrium, choose a larger one — the tool doesn't take atriums into consideration.

The results are approximate. However, this will allow you to verify the basis for the statement you receive at a mass retailer when they say, "It's for an 18-tatami room, so it's for an 18-tatami room." First, enter your region and insulation rating, and compare the results while switching the indicators.

▶ 動画を見る


FAQ

Q Is it not possible to determine the capacity of an air conditioner based solely on the room size (in tatami mats)?
A
It's impossible to determine that. The required capacity cannot be calculated without knowing four conditions: insulation performance, the number of windows facing west or east, the region, and the operating method. Even with the same 18 tatami mats, the recommended capacity will change depending on the insulation performance and operating method. The premise that it can be determined solely by "how many tatami mats it is" is incorrect.
Q Are there any free tools that can determine storage capacity?
A
Yes, there is. It's an air conditioner selection tool published by the Central Research Institute of Electric Power Industry, a think tank for the 10 major power companies. You can find it by searching for "ASST" on Google. A major improvement was made in January 2026, and it now allows you to select air conditioners for all 47 prefectures and up to the HEAT20 G2 level.
Q Is a 10-tatami mat size futon sufficient for an 18-tatami mat living/dining/kitchen area?
A
It depends on the conditions. In Hyogo Prefecture, on the first floor facing southeast, 18 tatami mats, with G2 level insulation, and only using the air conditioner when needed, the top-scoring unit was 2.8kW (equivalent to a 10-tatami mat room). This result shows that if the insulation performance is at the G2 level, a small capacity unit is sufficient without having to leave it on continuously.
Q Is there no point in buying an air conditioner with a kW or higher capacity?
A
This becomes less relevant when it comes to heating. Within the same performance group, the maximum capacity plateaus, so the difference in start-up time between 4kW and 6.3kW falls within the margin of error. The fact that tools show 4kW as the cheapest option when looking only at electricity costs supports this fact.
Q Is the same assessment applicable to houses with open-plan living spaces?
A
This tool is insufficient as is. Since it doesn't take into account a living room with a high ceiling, it's safer to choose a larger model than the one indicated by the tool's results if you have such a feature. Also, the solar heat gain calculations are not based on the same conditions as your own house, so the results should be treated as approximate.
Q Is there a way to shop at a mass retailer without losing money?
A
The key is to purchase by specifying the model number without mentioning the room's size in tatami mats. If you tell them the room size, they won't recommend smaller models. Beforehand, use a tool to determine the model number and specify, "I want this model number." The installation company will not refuse your order based on capacity.